立加报警说明 | ||
号码 | 英文注释 | 中文注释 |
2001 | OP EMERGENCY PB OR LS OFF | 急停开关被按下或轴向限位开关被碰到 |
2002 | MAIN SPINDLE SERVO ALM | 主轴伺服报警 |
2003 | CIRCUIT PROTECT TRIP | 电路保护故障 |
2004 | HYD。PUMP MOTOR OVERLOAD | 液压马达过载 |
2005 | HYD。PRESSURE DOWN ALARM | 液压压力低报警 |
2006 | HYD。PUMP MOTOR NOT RUN | 液压马达没有运转 |
2007 | SPINDLE STOP SIGNAL ALARM | 主轴停止信号报警 |
2008 | GEAR SHIFT CHECK SW。ALARM | 换挡检测开关报警 |
2009 | MAGAZINE EMG。STATUS | 刀库急停 |
2011 | MAIN POWER PHASE&ATC SWITCH ER | 总电相序或ATC开关错误 |
2015 | SPINDLE TOOL UNCLAMP ALARM | 主轴松刀报警 |
2017 | SPINDLE HEAD OIL OVERFLOW | 主轴冷却油过溢 |
2020 | CLT.&LUB&ATC.MOTOR OVERLOAD | 冷却,润滑,或ATC马达过载 |
2021 | AIR PRESSURE DOWN ALARM | 气压低报警 |
2022 | SPINDLE ORINETATION OVERTIME | 主轴定位超时 |
2023 | M06 COMMAND OVERTIME ALARM | M06命令超时报警 |
2024 | T.CODE COMMAND ERROR | T码命令错误 |
2025 | TOOL NO.SELECT KEEP/R NOT SET | 刀具号选择保持开关没有设定 |
2026 | GEAR SHIFT OVERTIME ALARM | 换挡超时报警 |
2027 | SPDL SPEED ARRIVAL ALARM | 主轴速度到达报警 |
2028 | SPINDLE ROTATION MALFUNCTION | 主轴旋转故障 |
2029 | APC DOOR OPEN | APC门被打开 |
2030 | TOOL CHANGE MOTOR BRAKE RLS | 换刀马达刹车释放 |
2031 | ATC MAINTENANCE STATUS INT | ATC维护状态 |
2032 | EXTERNAL FEED HOLD (OP PB SW) | 外部速率保持 |
2033 | SPINDLE HEAD OIL PUMPING ALARM | 主轴冷却油泵报警 |
2034 | CLNT W/TANK OR LEVEL SW ALARM | 冷却液水位低报警 |
2035 | TSC W/TANK MOTOR OVERLOAD | TSC冷却马达过载 |
2036 | TOOL SEARCH ILLEGAL ALARM | 刀具搜索违法报警 |
2037 | M06 COMMAND ILLEGAL ALARM | M06命令违法报警 |
2039 | MAG.MOVING ILLEGAL POS.ALARM | 刀库移动错误位置报警 |
2043 | 4-AXIS PRESSURE DOWN CHECK AL | 第四轴压力低检测报警 |
2045 | FIXTURE CLAMP/UNCLAMP ALARM | 夹具夹紧放松报警 |
2047 | ATC DOOR OPEN | ATC门被打开 |
2048 | OPERATORS SIDE DOOR OPEN | 操作门被打开 |
2050 | LUB.LEVEL LOW OR PRESSURE DOWN | 润滑油位低或压力低 |
2051 | OIL COOLING UNIT ALARM | 油温冷却器报警 |
2052 | COOLANT FILTER CHANGE ALARM | 冷却过滤器转换报警 |
2053 | COOLANT PRESSURE DOWN ALARM | 冷却液压力低报警 |
2054 | TOOL LIFE MANAGE MENT END ALARM | 刀具寿命结束报警 |
2058 | PARTS COUNT END ALARM | 工件计数结束报警 |
2060 | SPINDLE TOOL CL/UNCL ALARM | 主轴刀具夹紧/放松报警 |
2061 | TMG STOPPER IN/OUT ALARM | 刀库停止器进出报警 |
2062 | ATC CHANGER POS. ALARM | ATC 换刀位置报警 |
2063 | SAFETY SWITCH LOCKING ALARM | 安全开关锁定报警 |
2064 | WAIT.POT(MAG) SPD/MAG.SIDE AL | 刀库等待刀杯到主轴侧/刀库侧报警 |
2065 | CHANGER ARM POS.CHECK ALARM | 换刀臂位置检查报警 |
2066 | MUST BE COMMAND NEXT TOOL No. | 必须指定下一个刀号 |
2068 | ATC DOOR OPEN /CLOSE ALARM | ATC门开/关报警 |
2074 | ATC OVERTIME ALARM | ATC超时报警 |
2075 | ATC MAGAZINE ROT.OVERTIME ALARM | ATC 旋转超时报警 |
2077 | 4TH-AXIS CL/UNCL SW.ALARM | 第四轴夹紧放松开关报警 |
2079 | TOOL MAG.SYNCHRO MALFUNCTION | 刀库同步故障 |
2080 | ATC INTERLOCK ALARM | ATC 互锁报警 |
2081 | ATCMAGAZINE GUARD DOOR OPEN | ATC 刀库门开报警 |
2082 | ATC MAG.POT TOOL OUT SW.ALARM | 刀库刀杯出来报警 |
2083 | ATC MAINTENANCE STATUS | ATC维护状态 |
2084 | APC SET-UP STATION DOOR OPEN | APC安装站门开 |
2085 | THERMAL COMPENSATION ERROR | 热补偿错误 |
2087 | GEAR SHIFT LOST | 档位丢失 |
2088 | TOOL BREAKAGE | 刀具破损 |
2089 | TOOL WEAR DETECT | 刀具磨损检测 |
2090 | PALLET UNCLAMP STATUS | 工作台放松中 |
2094 | CHIP OR SCREW CONVEYOR ALARM | 排屑机报警 |
2099 | DRUM FILTER CHIP CLT.LOW LEVEL | 鼓式过滤器液面低 |
2101 | MUST BE RETUREND TO REF.POINT | 必须返回原点 |
2102 | CYCLE START IN FIXTURE UNCLAMP | 夹具放松时的循环启动 |
2103 | MUST BE ATC 1 CYCLE | ATC必须循环一次 K12.4=1 |
2104 | SPINDLE TOOL No .ZERO | 主轴刀号为0 |
2105 | ATC OP MAUAL MODE | ATC手动模式 |
2106 | APC OP MAUAL MODE | APC手动模式 |
2107 | FEEDRATE OVERRIDE 0% | 进给倍率选择开关为0 |
2108 | AUTO POWER OFF READY | 自动电源关准备中 |
2109 | MACHINE LOCK ON STATUS | 机床锁定中 |
2110 | AUXILIARY FUNC.M,S,T,LOCK ON | 辅助机能,即M,S,T锁定中 |
2111 | APC SET-UP SW.UNPUSH | APC设定按扭没有按下 |
2112 | MAN AXIS MOVING INTERLOCK | 手动轴移动互锁 |
2113 | SPDL STOP IN CUTTING MODE CMD | 切削模式主轴停 |
2114 | RST COMMAND ALARM ON STL | 复位命令报警 |
车床报警说明 | ||
序号 | 英文注释 | 中文注释 |
2001 | The Emergency push button s/w is pressed. The X or Zaxis multi-limit s/w is tripped out. | 急停按钮被按下或X,Z轴限位开关被压下 |
The x or z axis multi-limit switch is tripped out. | X,Z轴限位开关被压下 | |
2002 | The 1st spindle is in the Emergency status(It comes out when a 1st spindle alarm occurs) | 第一主轴在急停状态(主轴在报警状态此报警出现) |
2003 | The control circuit protectors are tipped out or fuse blown | 空气开关跳脱或保险丝熔断 |
2004 | The hydraulic motor is overloaded | 液压马达过载 |
2005 | The hydraulic pressure becomes below the set value.. | 油压压力在设定值以下 |
Trouble of hydraulic pressure s/w | 油压压力开关故障 | |
2007 | The zero-speed detection or the speed detection of spindel motor is not detected. | 主轴马达零速检测器或速度检测器无检测 |
2008 | Fault of gear shift confirmation switch. | 换挡开关出错 |
2009 | The 2nd spindle Emergency status.(It comes out when a 2nd spindle alarm occurs) | 第2主轴在急停状态(2主轴在报警状态此报警出现) |
2010 | Machine is in Not Ready status. | 机床准备不足状态 |
2012 | The X-axis torque limiter s/w is tripped out. | X轴扭力开关被绊住 |
Trouble of x-axis torque limiter switch | X轴扭力开关出错 | |
2013 | The Z-axis torque limiter s/w is tripped out. | Z轴扭力开关被绊住 |
Trouble of z-axis torque limiter switch | Z轴扭力开关出错 | |
2014 | The B-axis torque limiter s/w is tripped out. | B轴扭力开关被绊住 |
Trouble of B-axis torque limiter switch | B轴扭力开关出错 | |
2017 | The hydraulic oil of drain oil reservoir is overflowed. | 液压蓄油池过溢报警 |
Trouble of float switch in the oil reservoir | 液压蓄油池过溢出错 | |
2019 | Keep relay setting to define the machine model is not selected | 关于机床种类的K参数没有设定 |
2020 | The AC motor is overloaded.(coolant or lubrication pump motor) | 马达过载(冷却马达或润滑油马达) |
2021 | The Torque limit SKIP command is used incorrectly. | 使用扭力限制跳过命令出错 |
2022 | The spindle orientation command (m19) is not accepted. | 主轴定位命令没有执行 |
2023 | The tool change command is not accepted. | 换刀命令没有执行 |
2024 | Incorrect tool No.is commanded. | 错误的刀浩命令 |
2025 | Keep relay setting to define the tool post model is not selected | 控制刀塔型号的K参数没有设定 |
2026 | The gear shift command(M41/M42/M43/M44)is not accepted | 换挡命令没有执行 |
2027 | The spindle speed arrival signal is not detected. | 主轴速度抵达信号出错 |
2028 | Spindle rotation command(M03/M04)is not accepted. | 主轴旋转命令没有执行 |
2029 | The splash guard door is opened | 防溅门开 |
Trouble of door interlock limit switch | 门互锁限制开关故障] | |
2030 | Machine Lock command(M17/M18)is commanded in the improper mode. | 在不正确的模式执行机床锁定指令 |
2031 | The reference point return is not completed. | 原点复归没有完成 |
2032 | In auto mode ,FEED HOLD status | 自动模式下进给保持 |
2033 | Air pressure becomes below the set value | 气压在设定值以下 |
Trouble of Air pressure limit switch | 气压限位开关故障 | |
2034 | Proximity switch to detect the chucking confirmation is at a wrong position. | 卡盘夹紧近接确认开关位置错误 |
Trouble of chucking confirmation limit switch | 卡盘夹紧近接确认开关故障 | |
2035 | The axis change command is not accepted | 轴转换命令没有执行 |
2036 | Chuck clamp/unclump command (M68/M69) is not accepted. | 卡盘夹紧/放松命令没有执行 |
2037 | Proximity switch to detect the tailstock quill confirmation is at a wrong pos | 尾座套筒位置检测开关位置错误 |
Tailstock quill operation command (M78/M79)is not accetted | 尾座套筒伸出/收回命令没有执行 | |
Trouble of tailstock quill confirmation switch | 尾座套筒位置检测开关故障 | |
2038 | The Programmable Tailstock command(M46/M47) IS NOT accepted | 可程式尾座命令没有执行 |
2039 | The part catcher command(M10/M11) is not accepted | 工件收集器指令没有执行 |
2040 | The bar-feeder command(M50/M51) is not accepted | 棒料送料器指令没有执行 |
2041 | The alarm occurs at the Bar-feeder side. | 棒料送料器出现报警 |
2042 | The Auto door operation command (M52/M53)is not accepted | 自动门指令没有执行 |
2043 | The steady rest operation command (M38/M39/M58/M59) is not accepted | 中心架指令没有执行 |
2044 | The part catcher is advanced,even though M10 is not commanded | 即使M10没有指令,零件收集器也伸出 |
2045 | The Quick tool setter operation command(M80/M81)is not accepted. | 对刀仪命令没有执行 |
2046 | The chuck is opened,even though M69 is not commanded | 即使M69指令没有执行,卡盘还是打开 |
2047 | The encoder signal error for turret positioning is detected | 刀塔旋转指令编码器检测错误K5.4刀塔松开 |
2048 | The reset (RST)command is used while program is running | 程序运转中使用复位指令 |
2049 | The C-axis operation command(M88/M89/M90)is not accepted | C-轴松紧指令没有执行 |
2050 | Lack of lubrication oil. | 缺润滑油 |
2051 | Lack of coolant oil. | 缺冷却液 |
2052 | Trouble of proximity switch to detect chucking confirmation | 卡盘夹紧近接确认开关故障 |
2053 | Revolving tool is not engaged | 旋转刀具使用中 |
2055 | Synchronous command(M203/M204)is used in the improper condition | 同步运转指令使用不恰当 |
2056 | The M-codes for main and sub-spindle rotation,without M206 between those commands,is consecutively used. | 主轴和副主轴的M码使用问题 |
2057 | The tool life is reached at its expectancy | 刀具寿命超出设定范围 |
2058 | The parts counting is reached at the limit value set | 工件记数超出设定范围 |
2060 | The cycle start command is invalid because the chuck is not in clamp | 卡盘没有夹紧就执行循环启动 |
2062 | Trouble of the limit switch to detect the programmable tailstock operation | 可编程尾座限位开关故障 |
2063 | Trouble of proximity switch to detect the quick tool setter operation | 对刀仪运转检测开关故障 |
2090 | The feedrate value (f0%)srtter error | 被率设定为0错误 |
2093 | The reference point return is commaned,thougH each axis is alreAdy at its reference position | 执行原点复归指令,可是各轴已经在原点位置 |
2096 | The feedrate override is 0% | G01被率开关设定为0 |
2097 | The machine lock status | 机床锁定状态 |
2098 | The M00/M01 command status . | M00/M01状态 |
2099 | The M02/M30 command status . | M02/M30 状态 |
2061 | 安全门锁钥匙孔处处于打开状态,钥匙向左旋 |
报警表 | ||
1:紧急停止 | ||
编号 | 内容 | 恢复 |
AL01 | 紧急按钮或限位开关关闭 | |
控制板上某个急停按钮被按下。 | 释放急停按钮开关 | |
某个X轴,Y轴,Z轴的急停限位开关被按下。 | 用超程释放法解除限位开关 | |
短路/按钮开关或限位开关故障。 | 检查线路 | |
AL02 | 主轴系统报警,主轴系统出现异常。 | 参照主轴伺服系统说明书。 |
AL03 | 电路保护装置断路 | |
电路保护装置(QF21,QF22,QF23,QF24)断路 | 检查控制电源(AC,DC)及电路 | |
短路 | 重置控制电源 | |
AL04 | 液压泵电机过载 | |
液压泵或主轴箱润滑油泵的电机过载 | 检查电机和过载继电器 | |
检测过电流的微型继电器误动作 | ||
短路 | 检查电路 | |
AL05 | 液压压力下降(选项) | 检查液压动力装置 |
液压压力低于压力开关的设定值。 | ||
AL06 | 液压泵电机不转 | 检查磁性继电器 |
液压泵电机的磁性继电器故障 | ||
AL07 | 主轴停止信号故障 | 参照主轴伺服系统说明书。 |
AL08 | 齿轮速比范围检验开关故障 | 检查限位开关(SL12.SL13.SL14) |
主轴变速检测开关误动作 | ||
短路 | ||
AL11 | 主电源相序报警 | 检查电源连接 |
电源相序错误 | ||
AL15 | 主轴松刀报警 | 检查限位开关 (SL11) |
主轴松刀限位开关故障 | ||
短路 | ||
AL17 | 主轴冷却油溢出 | 检查回流油泵和油位开关(SV11) |
主轴内油位高于设定位置。 | ||
油位开关故障 | ||
AL19 | 机床型号的K参数没有设定 | 检查机床的型号和设定的K参数是否一致 |
设定正确的K参数 | ||
2:循环停止 | ||
AL20 | 冷却泵或润滑油泵马达过载 | 检查继电器和马达 |
冷却泵或润滑油泵马达过载 | ||
过电流检测继电器故障 | ||
短路 | ||
AL21 | 气压低报警 | 检查气源和气源管路 |
气压低于开关(SP12)的设定值 | ||
AL22 | 主轴定角度超时 | |
M19指令后,主轴定角度没有在15秒内完成 | 检查相应参数的设定值 | |
AL22 | 主轴定角度参数错误 | 检查位置编码器和电缆 |
主轴定角度编码器或其反馈电缆故障 | 重新调整定向 | |
AL23 | M06指令超时 | 根据ATC的交换顺序检查每一步的开关信号 |
M06指令后,换刀没有在30秒内完成 | ||
Y,Z轴的基准点信号或ATC的限位开关故障 | ||
AL24 | T代码指令错误 | 复位并输入正确的刀号 |
T指令 | ||
指令的刀号比主轴刀号相同 | ||
指令的刀号超出了刀库的最大容量号 | ||
AL25 | 刀库型号的K参数没有设定 | 设定正确的K参数 |
40把刀:D486-B3/K6-B3(FANUC 0M/16M,18M) | ||
60把刀:D486-B4/K6-B4 | ||
90把刀:D486-B5/K6-B5 | ||
120把刀:D486-B6/K6-B6 | ||
AL26 | 主轴换档超时 | |
换档没有在20秒内完成 | 检查齿轮,换档油缸等相关零件 | |
限位开关或电磁阀故障 | 检查开关,阀(SL12,SL13,SL14,YV14,YV15 | |
短路 | ||
AL27 | 主轴转速抵达超时 | 检查相关零件 |
指令转速20秒内没有检测到 | ||
主轴旋转参数输入错误 | 参看主轴系统说明书 | |
传动机构到达信号故障 | ||
AL28 | 主轴旋转故障 | |
没有输入S码或S码指令为0 | 输入正确的S码 | |
在不能使用的情况下,如主轴松刀状态指令转速 | 检查主轴的当前状态 | |
AL30 | 换刀马达刹车释放 | 操作完毕关闭其切换开关 |
马达刹车释放是为了旋转马达 | ||
AL31 | 必须返回原点 | 执行手动原点复归 |
关电再开,或机床锁定解除后,没有返回原点就执行循环启动指令 | ||
AL32 | 外部进给保持(操作面板按下了按钮开关) | |
主操作面板循环停止按钮被按下 | 检查按钮开关或线路 | |
短路 | ||
AL33 | 刀具破损检测 | 检查主轴刀具 |
检测到刀具破损 | ||
AL34 | 外部冷却单元报警 | 检查外部冷却单元 |
外部冷却单元故障 | ||
AL36 | T指令的不合理位置 | |
在不能使用的位置发出刀具搜索指令 | 检查ATC的状态及相关零件 | |
与ATC有关的开关发生故障 | ||
电磁阀故障 | ||
短路 | ||
AL37 | M06指令的不合理位置 | |
等待刀座没有在主轴侧时发出M06指令 | 检查ATC的状况及相关零件 | |
AL37 | 与ATC有关的开关发生故障 | 检查ATC的状况及相关零件 |
电磁阀故障 | ||
短路 | ||
AL38 | X轴APC交换位置开关报警 | 检查限位开关(SL63) |
托盘已经返回第一原点但APC位置开关还是关闭 | ||
限位开关或电磁阀故障 | ||
AL41 | APC 超时 | |
工作台交换没有在150秒内完成 | 检查APC顺序和有关零件 | |
限位开关或电磁阀故障 | ||
AL42 | M61/M62命令在错误位置 | APC返回初始位置 |
操作APC时不在初始位置 | ||
AL45 | B轴命令错误(包含小数点) | 重新执行 |
B轴没有在适当的位置夹紧 | ||
AL47 | ATC门开 | 关闭ATC门 |
ATC门关开关(SL56)关闭状态 | ||
ATC门处于打开状态 | ||
AL48 | 操作者一侧的开着 | 关门 |
操作者一侧的开着 | ||
开关故障 | ||
AL49 | 请关闭NC电源再开 | |
转动锁定状态的B轴出现的报警 | 请关闭NC电源再开 | |
AL50 | 润滑油油位降低或压力下降 | |
润滑油不足 | 加注润滑油 | |
油位开关故障 | 检查开关 | |
AL51 | 油温冷却器故障 | 参照油温冷却器说明书 |
AL52 | 主轴中心出水过滤网需要更换 | 更换过滤网 |
过滤器检测开关被激活 | 检查开关 | |
AL53 | 冷却液压力低报警 | 检测T-S-C装置 |
在T-S-C操作中压力低 | ||
AL55 | 循环启动中复位报警 | 检查坐标系并再次执行此操作 |
循环启动中有复位命令 | ||
AL57 | 等待刀座及刀库刀座刀具检测报警 | 检查开关 |
检测到在等待刀座或刀库刀座内有刀具处于异常状态 | ||
AL58 | 零件记数结束 | |
根据预设数值零件记数完毕 | ||
单纯报警状态 | ||
AL60 | 主轴刀具夹紧/放松报警 | |
松开/夹紧操作没有在10秒内完成 | 检查有关零件(SL11,YV11) | |
松开操作限位开关/电磁阀故障 | ||
AL61 | 刀库止动器进/出报警 | |
止动器进/出操作没有在15秒内完成 | 检查限位开关和阀(YV35,SL31,SL32) | |
限位开关或电磁阀故障 | ||
AL62 | ATC副手臂位置报警 | 检查开关/阀(YV41,YV42,YV43,YV44,SX41,SX42,SX43) |
副手臂上/下没有在25秒内完成 | ||
限位开关或电磁阀故障 | ||
AL63 | 副手臂进出报警 | |
副手臂进/出没有在15秒内完成 | 检查开关/阀(SL44,SL45,YV45) | |
限位开关或电磁阀故障 | ||
AL64 | 等待刀座主轴侧/刀库侧报警 | |
等待刀座的移动没有在15秒内完成 | 检查开关/阀(SL45A,SL5B,YV5A) | |
限位开关或电磁阀故障 | ||
AL65 | ATC主换刀臂位置检查报警 | |
ATC CAM没在原点位置 | 检测开关(SX51,SX52,SX53) | |
ATC 夹紧/放松开关没有同步 | ||
AL67 | ATC 必须手动循环一次 | |
ATC 用手操作 | ATC 用手动完成一次循环 | |
AL68 | ATC门开/关报警 | |
门没有在20秒内完成开/关 | 检查开关/阀(SL56,SL57,YV5S,YV5C) | |
限位开关或电磁阀故障 | ||
AL69 | APC交换臂开/合报警 | |
APC交换臂没有在25秒内完成 | 检查开关/阀(SX71,SX73,YV71,YV72) | |
开关或电磁阀故障 | ||
AL70 | APC 手臂上/下报警 | |
APC 手臂上/下动作没有在10秒内完成 | 检查开关/阀(SX83,SX84,YV75,YV76) | |
开关或电磁阀故障 | ||
AL71 | APC 转换臂180度CW/CCW报警 | |
APC 转换臂180度CW/CCW没有在25秒内完成 | 检查开关/阀(SX81,SX82,YV73,YV74) | |
开关或电磁阀故障 | ||
AL72 | B轴转台夹紧/放松开关报警 | 检查开关/阀(SP61,SL62,SP65,SP66,YV61,YV62,YV64) |
在NC检测到夹紧的情况下,B轴却是放松的。 | ||
夹紧放松的过程没有在15秒内完成 | ||
开关或电磁阀故障 | ||
AL73 | 第5轴夹紧/放松开关报警 | |
第5轴夹紧/放松没有在10秒内完成 | 检查开关/阀(SL91,SL92,SV91) | |
开关或电磁阀故障 | ||
AL74 | ATC 超时 | |
T指令或M06没有在45秒内完成 | 检查ATC顺序和有关开关 | |
开关或电磁阀故障 | ||
AL75 | ATC 刀库转动超时 | |
刀库转动没有在230秒内完成 | 检查相关开关(SX31,SX32 | |
开关或电磁阀故障 | ||
AL77 | 等待刀座和主轴刀具为0 | |
没有等待刀座或主轴刀具数据 | 输入刀具数据 | |
AL78 | ATC 面板操作手动开关打开状态 | |
ATC 面板操作开关在手动位置 | 转动开关到自动模式 | |
AL79 | 刀库同步故障 | |
刀库没有保持同步 | 把刀库旋转一周 | |
(一号刀没有找到) | 检查限位开关(SX31) | |
检测开关故障 | ||
AL80 | ATC或APC互锁报警 | |
坐标轴不能移动 | ||
ATC手臂不在原点位置 | 初始化ATC/APC | |
APC手臂不在初始位置 | ||
AL81 | 刀库门开 | |
刀库门开 | 关门或检测SL34开关 | |
开关坏 | ||
AL82 | 刀库卸刀器报警 | |
手动刀具拉出开关打开状态 | 检查开关或阀(SL33,YV34) | |
开关故障 | ||
AL84 | APC准备工位门开着 | |
准备工位门开着 | 关门或检查开关(S12) | |
开关故障 | ||
AL85 | 准备按钮没有按下 | |
在执行M60时按下准备按钮 | 按下准备按钮 | |
AL86 | APC面板手动开关被打开 | |
APC面板的模式开关被设置在手动位置 | 设置开关到自动模式 | |
AL87 | 主轴换档失败 | |
开电后没有指令换档命令 | 输入S码 | |
AL88 | 刀具监视器检测到刀具破损 | 更换破损刀具 |
AL89 | 刀具监视器检测到刀具磨损 | 更换磨损刀具 |
AL90 | B轴(工作台)或工作台夹紧报警 | 指令托盘或工作台夹紧 |
在B轴放松的状态下发出移动指令 | 检查开关(SP61,SP62) | |
AL91 | 机械干涉报警 | |
机械的当前坐标在干涉区域 | 移动坐标到自由区域 | |
AL92 | APC止动器进/出报警 | 检查开关或阀(SX87,SX88,YV84,YV85) |
APC止动器进/出没有在20秒内完成 | ||
开关或电磁阀故障 | ||
AL93 | 手动坐标轴移动互锁报警 | |
JOG模式进给坐标轴互锁 | 解除坐标轴互锁状态 | |
机床已经在原点位置又发出原点复归指令 | 执行原点复归-方向操作 | |
AL94 | 排屑机或螺旋排屑机报警 | |
输送电机过载 | 检查排屑机 | |
AL95 | 进给倍率为0 | |
G01速度调整开关被调整到0 | 检查开关 | |
AL96 | 自动电源关准备 | 检查自动电源关的拨动开关 |
AL97 | 机床锁定开关处于就绪状态 | |
机床锁定开关开 | 检查开关 | |
辅助锁定开关开 |